Determination of discharge velocity in the experimental flume, pressure measurement (digital display) Features - determination of discharge velocity using a pitotstatic tube Learning objectives/experiments Specification [1] determination of discharge velocity in the experimental flume HM 161 [2] determination of velocity via differential pressure [3] holder with vertical scale to indicate the position of the pitotstatic tube [4] hoses connect the pitotstatic tube and the battery operated differential pressure display [5] used together with HM 161.59 Technical data Scale - 0...800mm - graduation: 1mm Measuring ranges - differential pressure: 0...140mbar, resolution: 0,1mbar LxWxH: 300x300x1500mm Weight: approx. 6kg